Air chiller heat pump unit uniform control (40KW to 132KW)
TAE-R series modular air chiller unit work minus 25 degree, for summer cooling, and winter heating through fan coils, convectors, it produce hot water 45degC maximum, and can combine most 8 modulars as one group, set 1 unit as main modular and rest 7 units for sub modular to effect easy control.
It has Below add-on options:
1. Produce galvanized steel dark grey painting or white painting.
2. Cascade installation way.
Get a quick quote
Air chiller heat pump product features
- The modular air chiller unit produce with high-efficient scroll compressor Copeland.
- R410A or R407C refrigerant.
- Base frame external panels made of polyester powder coated steel or stainless steel.
- Reverse cycle valve.
- Compact structure and sound control design.
- Water side equipped with efficient tank type heat exchanger.
- Automatic anti-freeze and defrosting function.
- Careful protection functions as high pressure. low pressure, overheating, overload, anti-freezing, phase order, discharge temp, etc.
- General testing and operational test carried out for every unit before package in the factory
Frequently Asked Questions
What kind of care is needed for the heat pump?
There is no need, just clean up debris and snow around the heat pump in time.
What compressor your equipment have?
For all our products, best quality parts are adopted to assure heat pump good quality and good performance, like this compressor, always adopt branded America Copeland compressor or Japan Sanyo/Daikin compressor or Danfoss compressor.
What is the service life of the heat pump?
Linsam heat pumps are up to 25 to 30 years service life. During their lifetime, approximately 15 to 20 years is usually necessary to replace the heat pump compressor.
Are heat pumps noisy?
No. Heat pumps are generally not noisy. Noise is marginally higher than ambient background sound, and usually not annoying.
Do the products have CE?
Sure,all products are CE approval products, we produce according to international standard, products export to European market.
What is the cost of heat pump operation?
The only cost is the charge for the electricity required compressor and circulation water pump. It based on how many kilowatts are required for your house, generally heat pump is the most efficient way to heat your house, and you save lots of money. And if a room is well insulated, that will require less kw of heat pump, so you can choose smaller model.
Brands We Cooperate
Air chiller heat pump technical parameters
*Test conditions: (1). Rated cooling condition: Air source side DB/WB is 35℃/~, outlet water temp 7℃.
(2). Low temp heating: Air source side DB/WB is 7℃/6℃, outlet water temp 45℃.
(3). Super low temp heating: Air source side DB/WB is -12℃/-14℃, outlet water temp 41℃
Related products
EVI Cooling and heating unit 13KW
Air to water heat pump
Air heat pump cooling system (13KW to 18KW)
Air to water heat pump
High efficiency heat pump (25KW to 32KW)
Air to water heat pump