Product Catagory
Industrial air chiller unit (48KW to 157KW)
The classic air source heat pump TAN series usually applicable for normal temp or lower at -15°C, It is a high-efficiency, energy-saving, safe and environment-friendly high-tech heating/hot water equipment.
It has Below add-on options:
1. Produce stainless steel casing
2. Add electric bottom heater
3. Add soft starter
4. Wifi controller
Get a quick quote
Product Features
- High-efficient scroll compressor Copeland / Sanyo / Daikin.
- R410A or R407C or R417A refrigerant.
- Base frame external panels made of polyester powder coated steel or stainless steel.
- Reverse cycle valve.
- Compact structure and sound control design.
- Water side equipped with efficient tank type heat exchanger.
- Automatic anti-freeze and defrosting function.
- Careful protection functions as high pressure. low pressure, overheating, overload, anti-freezing, phase order, discharge temp, etc.
- General testing and operational test carried out for every unit before package in the factory
Classic air source heat pump options
We provide OEM and ODM services
Stainless steel casing
The heat pump cover produce with stainless steel casing can protect from rust, special by seaside installation.
Addon bottom heater
With eelctrical bottom heater tap by bottom of the air source heat pump, it avoid freezing of heat pump.
Addon ABB soft starter
We can install ABB soft starter for your heat pump, the unit start more smoothly from 0 to rated voltage.
Add on wifi controller
With wifi controller you can set the heat pump by telephone, with the code it more conventional for our life.
Main Components
Compressor
Our products adopts America Copeland scroll compressor for bigger heat pump and Panasonic compressor for smaller ones,, special designed for heat pump, working high efficiency.
Electronic expansion valve
With branded Sanhua expansion valve and combine with our company’s control system, we have developed a special electronic expansion controller that uses digital technology to adjust the refrigerant according to temperature factors to achieve the best flow rate effect and achieve higher COP.
Electrical control system
With project control function, it can easily control the circulating pump, water compensation, water supply, auxiliary electric heating, PID automatic defrost. Users can set different parameters according to different project needs, and automate the entire system.
Shell and tube heat exchanger
Linsam heat pump adopts high-efficiency shell and tube heat exchanger, the heat exchange area is 3.7 times that of bare tube, its unique design and compact spiral structure of the heat
exchanger ensures the full heat exchange of the refrigerant.
Technical Parameters
Model | TAN-15R | TAN-20R | TAN-25R | TAN-30R | TAN-50R |
---|---|---|---|---|---|
Heating capacity kW | 48.5 | 65.5 | 78.5 | 97.5 | 157 |
Input power kW | 13.8 | 18.5 | 23.5 | 27.5 | 47 |
Cooling capacity kW | 41.2 | 54.5 | 66.8 | 81 | 133.5 |
Input power kW | 13.5 | 17.5 | 22.1 | 26.2 | 44.2 |
Input current A | 20 | 26.51 | 33.1 | 40 | 66 |
Max running current A | 36 | 48 | 56 | 72 | 112 |
Power source | 380V/3N/50Hz | 380V/3N/50Hz | 380V/3N/50Hz | 380V/3N/50Hz | 380V/3N/50Hz |
Nosie level dB(A) | 66 | 68 | 68 | 68 | 72 |
Unit size mm | 1500x800x1500 | 1850x1000x1950 | 2000x1100x1930 | 2000x1100x2070 | 2300x1260x2250 |
Unit quality | 310 | 560 | 630 | 850 | 1350 |
Working temp range | -15℃-43℃ | -15℃-43℃ | -15℃-43℃ | -15℃-43℃ | -15℃-43℃ |
Refrigerant | R410A/R417A/R407C | R410A/R417A/R407C | R410A/R417A/R407C | R410A/R417A/R407C | R410A/R417A/R407C |
Refrigerant charge qty | 2.8*2 | 4.0*2 | 6.0*2 | 6.5*2 | 6.0*4 |
Compressor qty | 2 | 2 | 2 | 2 | 4 |
Water flow m3/h | 9.80 | 12.50 | 15.50 | 17.50 | 32.00 |
Conncetio in / out DN | 40 | 50 | 50 | 65 | 80 |
*Test condition 1. Cooling: ambient temp 35℃,AC side inlet water temp 1a2℃, outlet water temp is 7℃
2. Heating condition: Air source side DB/WB 7℃/6℃, AC side inlet water temp 40℃,outlet water temp 45℃
Related products
House heat pump cooling heating(6KW)
Air to water heat pump
Cooling heat pump system (9KW to 23KW)
Air to water heat pump
Heat pump with AC function (32KW to 40KW)
Air to water heat pump
Frequently Asked Questions
What kind of care is needed for the heat pump?
There is no need, just clean up debris and snow around the heat pump in time.
What compressor your equipment have?
For all our products, best quality parts are adopted to assure heat pump good quality and good performance, like this compressor, always adopt branded America Copeland compressor or Japan Sanyo/Daikin compressor or Danfoss compressor.
What is the service life of the heat pump?
Linsam heat pumps are up to 25 to 30 years service life. During their lifetime, approximately 15 to 20 years is usually necessary to replace the heat pump compressor.
Are heat pumps noisy?
No. Heat pumps are generally not noisy. Noise is marginally higher than ambient background sound, and usually not annoying.
Do the products have CE?
Sure,all products are CE approval products, we produce according to international standard, products export to European market.
What is the cost of heat pump operation?
The only cost is the charge for the electricity required compressor and circulation water pump. It based on how many kilowatts are required for your house, generally heat pump is the most efficient way to heat your house, and you save lots of money. And if a room is well insulated, that will require less kw of heat pump, so you can choose smaller model.